SET-560 AC Drive

SET-560 AC Drive

  • Close-loop vector control
  • Built-in PLC ,PID , AVR function
  • Torque control can be implemented in the CLVC mode.
  • Instantaneous power off , inverter keep running
  • Timing control function
  • Inovance MD380 software
  • General-purpose high-performance current vector control AC drive.
  • Implement the control of asynchronous motor
  • RPM Monitoring Feature,Auto Stand-by and Sleep Mode
  • Auto Stand-by and Sleep Mode
Item Specifications
Basic functions Maximum frequency 300Hz
Carrier frequency 0.5kHz~16.0kHz;Depending on the load Characteristics,and automatically adjust the carrier frequency.
Input frequency resolution Digital set:0.01Hz
Simulation set:The highest frequency×0.025%
Control mode V/F Control,SVC,FVC
Startup torque 150%
Speed range
1:100 (SFVC) 1:1000 (CLVC)
Speed stability accuracy
± 0.5% (SFVC) ± 0.02% (CLVC)
Overload capacity G type machine: 150%rated current 60s,180%rated current 3s
P type machine: 120% rated current 60s,150%rated current 3s
Torque boost Automatic torque boost;Manual torque boost 0.1%~30.0%
V/F curve Straight line V/F, Multi-point V/F,N-th power V/F
Ramp mode Straight-line ramp
S-curve ramp
Four groups of acceleration/deceleration time with the range of 0.0–6500.0s
DC braking DC braking frequency: 0.00 Hz to maximum frequency
Braking time: 0.0–100.0s
Braking action current value: 0.0%~100.0%
JOG control JOG frequency range: 0.00–50.00 Hz
JOG acceleration/deceleration time: 0.0–6500.0s
Onboard multiple preset speeds It implements up to 16 speeds via the simple PLC function or combination of DI terminal states.
Onboard PID It realizes process-controlled closed loop control system easily.
Auto voltage regulation (AVR) It can keep constant output voltage automatically when the mains voltage changes.
Overvoltage/ Overcurrent stall control The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to overvoltage/overcurrent.
Fast current limit function Minimize the over-current fault,and protect the normal operation of the AC drive.
Torque limit and control It can limit the torque automatically and prevent frequent over current tripping during the running process. Torque control can be implemented in the CLVC mode.
Individualized functions High performance Control of asynchronous motor and synchronous motor are implemented through the high-performance current vector control technology.
Power dip ride through The load feedback energy compensates the voltage reduction so that the AC drive can continue to run for a short time.
Timing control Time range: 0.0–6500.0 minutes
RS485 bus support Modbus-RTU protocol
Running Running command source Operation panel
Control terminals
Serial communication port
You can perform switch over between these sources in various ways.
Frequency source There are a total of 13 frequency sources, such as digital setting, analog voltage setting, analog current setting, pulse setting and serial communication port setting,variety of speed PLC, PID. You can perform switch over between these sources in various ways.
Auxiliary frequency source There are 13 auxiliary frequency sources. It can implement fine tuning of auxiliary frequency and frequency synthesis.
Input terminals 5 digital input (DI) terminals, X5 supports up to 100 kHz high-speed pulse input;
2 analog input (AI) terminals, A1 only supports 0–10 V voltage input and A2 supports 0–10 V voltage input or 4–20 mA current input.
Output terminals 1 high-speed pulse output terminal (open-collector) that supports 0–100 kHz square wave signal output
1 digital output (DO) terminal 2relay output terminals
2 analog output (AO) terminals that supports 0–20 mA current output or 0–10 V voltage output.
Display and keyboard LED display Display parameters (three display modes: Basic Mode, Quick Menu mode, non-factory value mode).
Protection mode Motor short-circuit detection at power-on, input/output phase loss protection, over current protection, over voltage protection, under voltage protection, overheat protection and overload protection.
Optional parts Braking unit, I/O extension card, RS485 communication card, PROFIBUS-DP communication card, differential input PG card, OC input PG card.
Environment Installation location Indoor, free from direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapour, drip or salt.
Altitude Lower than 1000 m
Ambient temperature -10°C to +40°C (de-rated if the ambient temperature is between 40°C and 50°C).
Humidity Less than 95%RH, without condensing
Vibration Less than 5.9 m/s2 (0.6 g)
Storage temperature -20℃~+60℃
control circuit control circuit
  • applications
  • applications
  • applications
  • applications
  • applications

our clients

Komal Tex Fab Pvt.Ltd
Gopi Sysnthetic Limited
Ozone Spintex Private Limited
Rankas Tex fab Pvt.Ltd
Jindal Texofab
Parth International
Sekhani Group
Anjani Sysnthetic Limited
Mahalaxmi Group Fabric Division
Kanti Fashion
Vinny Overseases Limited
CTM Textile Mills
Parth International
Chiripal Industries Limited
Kankariya Textile Industries Pvt.Ltd
Vishal Fabric Limited